KDE Partition Manager: SMART Status Report

Date: 14/12/2025 09:32
Program version: 23.08.5
Backend: pmsfdiskbackendplugin (1)
KDE Frameworks version: 5.115.0
Machine: Linux optiplex 6.14.0-36-generic #36~24.04.1-Ubuntu SMP PREEMPT_DYNAMIC Wed Oct 15 15:45:17 UTC 2 x86_64

SMART status: good
Model: SanDisk SSD PLUS 1000GB
Serial number: 19360S465503
Firmware revision: UH5100RL
Temperature: 26° C / 79° F
Bad sectors: none
Powered on for: 717 days and 22 hours
Power cycles: 2,832
Self tests: Success
Overall assessment: Healthy

5 Reallocated Sectors Count
Count of reallocated sectors. When the hard drive finds a read/write/verification error, it marks this sector as "reallocated" and transfers data to a special reserved area (spare area).
Old-Age Online 100 100 0 0x000000000000 N/A 0 sectors
9 Power-On Hours
Count of hours in power-on state.
Old-Age Online 100 100 0 0x00000000434e N/A 717 days and 22 hours
12 Power Cycle Count
Count of full hard disk power on/off cycles.
Old-Age Online 100 100 0 0x000000000b10 N/A 2,832
165
Old-Age Online 100 100 0 0x000000000d3b N/A N/A
166
Old-Age Online 100 100 0 0x000000000005 N/A N/A
167
Old-Age Online 100 100 0 0x000000000000 N/A N/A
168
Old-Age Online 100 100 0 0x00000000000b N/A N/A
169
Old-Age Online 100 100 0 0x000000000385 N/A N/A
170 SSD Available Reserved Space
Number of available reserved space as a percentage of reserved space.
Old-Age Online 100 100 0 0x000000000000 N/A N/A
171 SSD Program Fail Count
Number of flash program operation failures since the drive was deployed.
Old-Age Online 100 100 0 0x000000000000 N/A 0
172 SSD Erase Fail Count
Number of flash erase operation failures since the drive was deployed.
Old-Age Online 100 100 0 0x000000000000 N/A 0
173 SSD Wear Levelling Count
Counts the maximum worst erase count on any block.
Old-Age Online 100 100 0 0x000000000005 N/A N/A
174 SSD Unexpected power loss count
Number of shutdowns without STANDBY IMMEDIATE as the last command (regardless of PLI activity using capacitor power). Normalised value is always 100.
Old-Age Online 100 100 0 0x0000000001e7 N/A N/A
184 End-to-End Error
Part of HP's SMART IV technology: After transferring through the cache RAM data buffer the parity data between the host and the hard drive did not match.
Old-Age Online 100 100 0 0x000000000000 N/A 0
187 Reported Uncorrectable Errors
Count of errors that could not be recovered using hardware ECC.
Old-Age Online 100 100 0 0x000000000000 N/A 0 sectors
188 Command Timeout
Count of aborted operations due to HDD timeout.
Old-Age Online 100 100 0 0x000000000000 N/A 0
194 Temperature
Current internal temperature.
Old-Age Online 74 74 0 0x004a0009001a N/A 26° C / 79° F
199 UltraDMA CRC Error Count
Count of errors in data transfer via the interface cable as determined by ICRC.
Old-Age Online 100 100 0 0x000000000000 N/A 0
230 GMR Head Amplitude
Amplitude of "thrashing" (distance of repetitive forwards/reverse head motion)
Old-Age Online 100 100 0 0x094301000943 N/A N/A
232 Endurance Remaining
Count of physical erase cycles completed on the drive as a percentage of the maximum physical erase cycles the drive supports
Pre-Failure Online 100 100 5 0x000000000064 good N/A
233 Power-On Seconds
Time elapsed in the power-on state
Old-Age Online 100 100 0 0x000000001577 N/A N/A
234 Unrecoverable ECC Count
Count of unrecoverable ECC errors
Old-Age Online 100 100 0 0x00000000cec6 N/A 52,934 sectors
241 Total LBAs Written
Total LBAs Written
Old-Age Offline 100 100 0 0x0000000050b1 N/A N/A
242 Total LBAs Read
Total LBAs Read
Old-Age Offline 100 100 0 0x000000002343 N/A N/A
244
Old-Age Online 100 -1 0 0x000000000000 N/A N/A